RO Disinfectant Chemical for Haridwar's Membrane Sanitization
Microbial fouling is one of the hardest problems to detect in an RO system — until it is too late. Biofilm builds silently on membrane surfaces, slowly reducing flux, increasing pressure drop, and creating a breeding ground for further contamination. Innova Corporate (India) manufactures a non-oxidizing RO Disinfectant specifically designed to eliminate this problem in industrial plants across Haridwar, SIDCUL, BHEL and Roorkee. It kills microorganisms without attacking the membrane itself.
The formulation is a broad-spectrum microbiocide that works by disrupting microbial cell function rather than oxidising it. This is critical for Polyamide and TFC membranes — chlorine and other oxidisers would destroy them, but this non-oxidising chemistry leaves the membrane fully intact. It penetrates established biofilm, breaks it down, and flushes it out during the cleaning cycle. The result is restored performance and a sanitised system ready for continued operation.
Key Features & Strategic Benefits for Local Plants:
- Broad-Spectrum Efficacy: Highly effective against a wide range of microorganisms, preventing bio-fouling and pressure drops in high-load industrial systems.
- Potable Water Safe: Certified safe for use in RO systems producing drinking water when used as per guidelines.
- Non-Oxidizing Formula: Unlike chlorine, it does not oxidise or degrade Polyamide or TFC membranes.
- Eco-Friendly & Biodegradable: Environmentally responsible formulation that breaks down safely after use, meeting the region's discharge standards.
- Total System Compatibility: Fully compatible with all RO membrane components, housings, and high-pressure pumps.
Application & Dosage Guidelines:
Dosage depends on the severity of biological fouling. We recommend two primary methods for industrial facilities:
- Shock Dosing (Immediate Disinfection): Use a concentration of 5–10% v/v for rapid system sterilisation during shutdowns.
- Continuous Dosing (Preventative): Maintain a concentration of 2.5 ppm on the feed water for round-the-clock microbial control.
Where It Is Used in the Region:
Plants across the Ganga belt rely on this disinfectant as a standard part of their membrane hygiene programme. Common applications include:
- Pharma units — sanitising RO membranes where microbial contamination would fail quality standards.
- FMCG and food processing plants — controlling biofilm in process water systems.
- Heavy engineering units — protecting membrane systems fed by Ganga canal water with high seasonal microbial loads.
- Drinking water and packaged water plants — ensuring microbial safety in potable applications.
- Cooling tower and utility water systems — controlling bio-slime that affects heat exchange efficiency.
Recommended Membrane
Cleaning Protocol:
- Disinfect the system with Innova RO Disinfectant.
- Flush thoroughly with permeate water.
- Circulate a High pH Membrane Cleaner solution for 30 minutes,
then soak for 1–2 hours.
- Final flush with permeate water before returning the plant to normal service.
*Note: In multi-pass
systems, clean each pass individually for the best results. Replace cleaning
solutions if they become excessively turbid.*
Safety & Handling: Proper PPE (splash goggles, lab coats, gloves, and
vapor respirators) must be worn. Store in original containers in a cool, dry place
at your site, away from direct heat or sunlight.