• 2B / BW Shalimar Bagh, Opp. BQ Market, Near DLF Mall New Delhi - 110088, India.
  • :+91-9312-871-070
Sodium Bisulfite Dechlorination for Mombasa Industrial RO Feed Water - Innova Corporate India

RO Dechlorination Chemicals in Mombasa (Sodium Bisulfite for Chlorine & Chloramine Removal)

Innova Corporate (India) supplies RO Dechlorination Chemicals in Mombasa for plants that use chlorination as part of their pre-treatment programme. Many industrial and commercial RO facilities on the Kenyan coast chlorinate feed water for disinfection and algae control, then must remove that chlorine before it reaches the membranes. This chemical does exactly that — it neutralises free chlorine and chloramines in seconds, protecting downstream RO membranes from oxidative damage. If your Mombasa plant uses chlorine anywhere in its pre-treatment — seawater intake, process water disinfection, or potable water treatment — you need dechlorination before the RO membranes.

Our RO de-chlorinator is a concentrated, stabilised liquid sodium bisulfite formulation designed for complete chlorine elimination. It reacts with free chlorine and chloramines to form harmless sulfate and chloride — no toxic by-products, no membrane damage. Unlike raw sodium bisulfite powder, our stabilised liquid maintains activity in Mombasa's warm coastal climate and monsoon-driven humidity variations. It is compatible with all polyamide and TFC membranes and is the standard dechlorination chemical used in port, industrial and commercial RO plants across the Kenyan coast.

The Dechlorination Reaction — What Happens at the Molecular Level:

Chlorine attacks RO membranes through oxidation. Sodium bisulfite stops this by reacting with chlorine before it reaches the membrane surface. The chemistry is simple and fast:

Step Reaction Result
1. Chlorine in feed water Cl₂ + H₂O → HOCl + HCl Hypochlorous acid (oxidising agent)
2. Sodium bisulfite added NaHSO₃ + HOCl → NaHSO₄ + HCl Harmless sulfate + chloride
3. Result No free chlorine reaches membrane Membrane surface stays intact

The reaction is near-instantaneous at ambient temperature — complete within seconds of contact. This is why ORP monitoring at the membrane inlet is critical: if ORP rises above 200 mV, chlorine is passing through.

What Makes This Dechlorination Chemical Different:

  • Stabilised Liquid Form: Unlike raw sodium bisulfite powder that degrades in tropical humidity, our stabilised liquid maintains full activity in Mombasa's warm, humid climate.
  • Chloramine Removal: Not just free chlorine — this formulation also breaks down chloramines formed when ammonia is present in Changamwe or Miritini groundwater.
  • Instant Reaction: Near-instantaneous chlorine neutralisation — no contact tank required, just a dosing point before the cartridge filter.
  • No pH Shift: Unlike caustic or acidic dechlorinators, this formulation has minimal impact on feed water pH — antiscalant performance is not affected.
  • Antiscalant Compatible: Can be dosed before antiscalant without neutralising either chemical — just space the dosing points 3–5 meters apart.
  • ORP-Clear Indicator: Reaction endpoint is visible on ORP meter — target below 200 mV at membrane inlet for complete dechlorination.
  • Low Dosage: Only 1.5–3 ppm sodium bisulfite per ppm of chlorine — cost-effective for high-flow Mombasa port and industrial RO plants.
  • NEMA Compliant: Reaction products (sulfate, chloride) are harmless at discharge concentrations, meeting Kenya NEMA coastal discharge guidelines.

Where Dechlorination is Needed in Mombasa — Plant Types:

Seawater Intake with Chlorination: Facilities that chlorinate seawater intake for algae and mussel control — including port and coastal industrial SWRO plants — require dechlorination before the RO membranes.

Municipal Water with Chlorine Residual: Plants drawing chlorinated municipal water as RO feed need dechlorination to protect membranes from the chlorine residual in the supply.

Borewell Water with Shock Chlorination: Facilities that periodically shock-chlorinate borewells or storage tanks need temporary high-dosage dechlorination during the post-shock period.

Process Water Disinfection: Plants that chlorinate process water for hygiene — food processing, beverage, pharmaceutical — need dechlorination before the RO polishing stage.

Cooling Tower Blowdown Reuse: Facilities reusing cooling tower blowdown (which often contains chlorine) as RO feed require dechlorination before the membranes.

CIP Rinse Water: RO membranes rinsed with chlorinated water after CIP need dechlorination to prevent oxidation during the rinse step.

Dechlorination vs Other Pre-Treatment Chemicals — Where It Fits:

Chemical Purpose Dosing Point
Coagulant Neutralise particle charge Raw water intake
Flocculant Bind particles into flocs After coagulant
Dechlorination Remove chlorine After media filter, before cartridge filter
Antiscalant Prevent scale Before membranes (after dechlorination)
Biocide Control microbes Before membranes

Order matters: Dechlorination must happen BEFORE antiscalant and biocide dosing. If chlorine is present when antiscalant is added, chlorine neutralises the antiscalant and both become ineffective.

Dosing & Monitoring — Practical Guide for Mombasa Plants:

  • Dosage Calculation: For every 1 ppm of free chlorine in feed water, dose 1.5 ppm sodium bisulfite. For chloramines, dose 3 ppm per ppm of chloramine.
  • Typical Range: 3–15 ppm in Mombasa feed water, depending on chlorine residual. Port SWRO with algal bloom pre-chlorination may need up to 15 ppm.
  • Dosing Method: Metering pump into feed line — no contact tank required. Reaction is instantaneous.
  • ORP Monitoring: Install ORP probe at membrane inlet. Target below 200 mV. If ORP rises, increase dechlorinator dosage immediately.
  • DPD Testing: Weekly DPD test to confirm free chlorine below 0.05 ppm at membrane inlet. This is the definitive check.
  • Storage: Store in original sealed container, away from direct sunlight. In Mombasa's hot climate, store in shaded, ventilated area. Shelf life 12 months.

Chlorine Damage — What Actually Happens to a Mombasa RO Membrane:

Hour 1–24: Membrane surface begins to oxidise. Salt rejection drops slightly — may not be noticed without daily monitoring.

Day 2–7: Oxidation spreads deeper into the polyamide layer. Salt rejection drops by 5–10%. Permeate conductivity rises.

Week 2–4: Irreversible damage. Salt rejection drops by 20% or more. The membrane cannot be restored by any cleaning method.

Month 2+: Membrane replacement required. Cost: 5–10× the cost of the dechlorination chemical that would have prevented it.

The bottom line: Dechlorination is the cheapest insurance policy in RO pre-treatment. A 20L container of sodium bisulfite costs a fraction of one membrane element.

Technical Specifications:

Appearance Clear to pale yellow liquid
Active Ingredient Sodium bisulfite (stabilised, 30–40% w/w)
pH (as is) 3.5 – 5.0
Specific Gravity 1.20 – 1.35
Reaction Time Instantaneous (within seconds)
Recommended Dosage 1.5 ppm per ppm chlorine (free) / 3 ppm per ppm chloramine
Shelf Life 12 months in original sealed container
Certification NEMA compliant

Frequently Asked Questions (Mombasa):

Q: How do I know if my Mombasa RO plant needs dechlorination?
A: Check your pre-treatment programme. If you chlorinate anywhere — seawater intake, process water, or municipal feed — you need dechlorination before the RO membranes. Also, if your permeate conductivity rises without scale or biofilm explanation, chlorine oxidation may be the cause.

Q: What is the difference between free chlorine and chloramine removal?
A: Free chlorine (HOCl) is easier to neutralise — 1.5 ppm sodium bisulfite per ppm. Chloramines (formed when ammonia is present) require 3 ppm per ppm. Our stabilised formulation handles both — just adjust dosage based on DPD test results.

Q: Can I use raw sodium bisulfite powder instead of this liquid formulation?
A: You can, but powder requires dissolution in a mixing tank, adds labour, and degrades quickly in Mombasa's humid climate. Our stabilised liquid is ready to dose, maintains activity, and gives consistent results with no mixing.

Q: How do I know dechlorination is working?
A: Two checks: (1) ORP at membrane inlet below 200 mV; (2) DPD test showing free chlorine below 0.05 ppm. If both pass, dechlorination is working. If either fails, increase dosage immediately.

Q: Will dechlorination affect my antiscalant?
A: No — if dosed correctly. Dechlorination must happen BEFORE antiscalant dosing, with 3–5 meters spacing between injection points. Never mix the two chemicals directly.

Q: How much dechlorination chemical does my Mombasa plant need annually?
A: This depends on feed chlorine level and flow rate. For a typical 100 m³/hr port SWRO with 1 ppm chlorine residual, expect approximately 200–400 litres per year of sodium bisulfite liquid. Contact us for a plant-specific estimate.

Handling & Safety:

Sodium bisulfite reacts with acids to release sulfur dioxide gas. Always wear splash goggles, chemical-resistant gloves and apron during handling. Store away from acids and oxidisers in a cool, shaded area at your Mombasa facility. In case of skin or eye contact, flush with plenty of water. Refer to the Material Safety Data Sheet (MSDS) for comprehensive safety data.

*Note: Innova Corporate recommends consulting our service engineers in Mombasa for precise dosage requirements based on your specific water chemistry and chlorine levels. Free water analysis and dosage calculation available on request.