Innova Corporate (India) supplies non-oxidizing Membrane Biocides in Singapore for NEWater RO post-treatment, pharmaceutical water systems in Tuas and Woodlands, marine vessel RO units in Singapore shipyards, and Jurong Island petrochemical cooling towers. Biofouling is one of the most persistent problems in Singapore RO systems — bacteria, fungi, algae and sulfate-reducing bacteria (SRB) form biofilm layers on membrane surfaces that reduce permeate flow, raise differential pressure and increase energy cost. Chlorine-based biocides cannot be used directly on polyamide membranes because they cause irreversible oxidation damage. Our non-oxidizing biocides control microbial growth without attacking membrane surfaces, making them the preferred choice for Singapore NEWater, pharmaceutical and marine plants.
Our biocide range is designed for continuous feed dosing or intermittent CIP sanitisation of RO, NF and UF membranes used across Singapore. It is highly effective against a broad spectrum of microorganisms — bacteria, fungi, algae, viruses and SRB — at low dosage, reducing chemical consumption cost for Singapore plants. The liquid formulation is easy to dose with standard metering pumps and is compatible with all major membrane brands. For NEWater and pharmaceutical water systems, food-grade formulations are available that comply with PUB water quality guidelines and HSA/PIC-S requirements.
NEWater Plants (PUB): NEWater RO systems use non-oxidizing biocide for continuous feed dosing to control algae and biofilm without damaging membranes.
Pharmaceutical Water Treatment (Tuas, Woodlands): Pharma plants use food-grade non-oxidizing biocide for residue-free sanitisation of purified water systems, meeting HSA and PIC/S guidelines.
Marine Vessels & Shipyards: Marine RO units on vessels and offshore platforms in Singapore use non-oxidizing biocide to control biofilm without corroding system metallurgy.
Jurong Island Petrochemical: Large petrochemical cooling towers use non-oxidizing biocide to control SRB and biofilm without corrosion risk.
Semiconductor Ultrapure Water: Semiconductor fabs in Woodlands and Tuas use non-oxidizing biocide for residue-free sanitisation of ultrapure water RO systems.
Food & Beverage Processing: Food factories across Singapore use non-oxidizing biocide for CIP of process water RO systems between production batches.
| Parameter | Chlorine (Oxidizing) | Non-Oxidizing Biocide |
|---|---|---|
| Effect on Polyamide Membranes | Degrades membrane surface | Safe for polyamide and TFC |
| Effect on Cooling System Metallurgy | Corrosive at high doses | Non-corrosive to steel and copper |
| SRB Control | Limited — does not penetrate biofilm | Penetrates biofilm and kills SRB |
| Dechlorination Step | Required before RO membranes | Not required |
Biofilm Formation: Bacterial slime layers that resist standard cleaning. Non-oxidizing biocide penetrates and breaks down the biofilm matrix.
Sulfate-Reducing Bacteria: Thrive in anaerobic zones of Jurong Island petrochemical cooling systems and produce hydrogen sulfide that corrodes steel and damages membranes.
Algal Growth in NEWater Intakes: Seasonal algal blooms in Singapore reservoir and coastal intakes introduce organic matter and microbial load.
Marine Vessel Biofouling: Marine RO units operating in Singapore coastal waters face high microbial load from seawater and onboard processes.
Semiconductor Ultrapure Water Contamination: Trace microbial contamination in semiconductor RO systems requires residue-free, non-oxidizing disinfection.
Membrane Flux Decline: Biofilm deposits cause gradual but persistent loss of permeate flow and rising differential pressure.
| Appearance | Clear to pale yellow liquid |
| Type | Non-oxidizing organic biocide |
| pH (as is) | 6.0 – 8.0 |
| Specific Gravity | 1.02 – 1.10 |
| Recommended Dosage | 2–10 ppm (continuous) / 50–200 ppm (CIP) |
| Solubility | Fully miscible in water |
| Shelf Life | 12 months in original sealed container |
Q: What are membrane biocides used for in Singapore RO systems?
A: They control microbial growth and biofouling in RO membranes at NEWater plants, pharmaceutical water systems, marine vessel RO units and Jurong Island cooling towers. They kill bacteria, fungi, algae and SRB that form biofilm on membrane surfaces.
Q: Why are non-oxidizing biocides preferred for Singapore RO systems?
A: Non-oxidizing biocides do not attack polyamide or TFC membranes, unlike chlorine. This makes them the preferred choice for NEWater, pharmaceutical and marine RO systems in Singapore where membrane integrity is critical.
Q: Which Singapore industries use membrane biocides the most?
A: NEWater plants, pharmaceutical water treatment facilities in Tuas and Woodlands, marine vessel RO systems in Singapore shipyards, Jurong Island petrochemical cooling towers, and semiconductor ultrapure water systems.
Q: How do membrane biocides control sulfate-reducing bacteria in Singapore?
A: Non-oxidizing biocides penetrate biofilm and kill SRB without oxidizing metal surfaces, protecting both membranes and system metallurgy in Jurong Island cooling systems and other Singapore plants.
Q: What dosage of membrane biocide is recommended for Singapore RO systems?
A: Typical dosage is 2–10 ppm for continuous feed dosing, or 50–200 ppm for CIP sanitisation. Our team provides free dosage guidance based on feed water analysis for Singapore plants.
Q: Do you supply membrane biocides across Singapore industrial areas?
A: Yes, we supply to NEWater, pharmaceutical, marine, petrochemical and semiconductor RO plants across Singapore, including Jurong Island, Tuas, Woodlands, Changi and Pioneer.
Storage & Handling: Store in original, tightly sealed containers in a cool, dry and well-ventilated area at your Singapore facility. Keep away from direct sunlight, heat sources and incompatible materials. For detailed dosing instructions, efficacy data and safety protocols, please refer to the Technical Data Sheet (TDS) and Material Safety Data Sheet (MSDS).
Related Products: Explore our Silver Hydrogen Peroxide Disinfectant, Low pH Membrane Cleaner, and RO Antiscalant Range for a complete RO chemical programme across Singapore.