Innova Corporate (India) supplies RO Membrane Disinfectant and Non-Oxidizing Biocide in Muscat for cooling towers, process water systems and industrial RO plants where chlorine cannot be used. Cooling towers in Al Rusayl and refinery process water loops near Sohar face continuous microbial load from algae, bacteria and sulfate-reducing bacteria (SRB). SRB in particular thrive in anaerobic zones of cooling systems and produce corrosive hydrogen sulfide that damages both metallurgy and membranes. Our non-oxidizing biocide penetrates biofilm, kills SRB and algae, and protects the entire water circuit without oxidizing polyamide or TFC membranes.
We offer a comprehensive range of disinfection technologies for Muscat industries — including non-oxidizing biocides, silver hydrogen peroxide-based disinfectants and peracetic acid formulations. Continuous dosing of these biocides prevents the classic symptoms of biofouling in Muscat plants: rising power consumption, reduced flow rates, higher differential pressure and compromised permeate quality. Because they are non-oxidizing, they eliminate the need for complex chlorination and dechlorination steps in feed water pre-treatment — a major advantage for refinery and power plant operators in Muscat.
Cooling Tower Operators (Al Rusayl, Sohar): Continuous biocide dosing controls algae, bacteria and SRB in cooling water circuits, reducing corrosion and improving heat transfer efficiency.
Oil & Gas Refineries (Sohar): Process water and injection water systems use non-oxidizing biocide to control SRB and biofilm without damaging metallurgy or membranes.
Power Generation Plants: Cooling tower make-up and boiler feed RO systems in Muscat use non-oxidizing biocide to prevent microbial growth without chlorine-related corrosion.
Industrial Process Water: Manufacturing units across Muscat use biocide for CIP and continuous dosing of RO systems where chlorine compatibility is a concern.
| Parameter | Chlorine (Oxidizing) | Non-Oxidizing Biocide |
|---|---|---|
| Effect on Polyamide Membranes | Degrades membrane surface | Safe for polyamide and TFC |
| Effect on Cooling System Metallurgy | Corrosive at high doses | Non-corrosive to steel and copper |
| SRB Control | Limited — does not penetrate biofilm | Penetrates biofilm and kills SRB |
| Dechlorination Step | Required before RO membranes | Not required |
Sulfate-Reducing Bacteria (SRB): Thrive in anaerobic zones of Muscat cooling systems and produce hydrogen sulfide that corrodes steel and damages membranes.
Algal Growth in Cooling Towers: Sunlight and warm temperatures in Muscat accelerate algae growth in open cooling tower basins, reducing heat transfer efficiency.
Biofilm Formation on Membranes: Persistent biofilm layers resist standard cleaning and cause rising differential pressure and falling permeate flow.
Legionella Risk: Warm cooling water in Muscat is a favourable environment for Legionella growth. Non-oxidizing biocide dosing reduces this risk.
| Appearance | Clear to pale yellow liquid |
| Active Ingredient | Non-oxidizing organic biocide |
| pH (as is) | 6.0 – 8.0 |
| Specific Gravity | 1.02 – 1.10 |
| Recommended Dosage | 50–200 ppm (cooling tower) / 100–200 ppm (CIP) |
| Shelf Life | 12 months in original sealed container |
Q: Can I use this biocide in both cooling tower and RO membrane applications?
A: Yes. The same non-oxidizing biocide works for cooling tower continuous dosing and RO membrane CIP sanitisation. Dosage differs — 50–200 ppm for cooling towers and 100–200 ppm for CIP shock dosing.
Q: Why is non-oxidizing biocide better than chlorine for Muscat cooling towers?
A: Chlorine is corrosive to cooling system metallurgy and degrades polyamide RO membranes. Non-oxidizing biocide penetrates biofilm, controls SRB and is safe for both metals and membranes.
Q: How do I control SRB in Muscat cooling systems?
A: Continuous dosing of non-oxidizing biocide at 50–200 ppm penetrates anaerobic biofilm zones and kills SRB. Regular monitoring of microbial counts confirms effectiveness.
Q: Is this biocide safe for potable water RO systems?
A: Yes, potable-grade formulations are available for municipal and community RO systems in Muscat, compliant with Omani drinking water standards.
Q: What dosage is recommended for Muscat cooling towers?
A: Typical dosage is 50–200 ppm in recirculating water, based on biological load and blowdown rate. Our technical team provides free dosage guidance for Muscat facilities.
Q: Do you supply non-oxidizing biocide across Muscat industrial areas?
A: Yes, we supply to cooling towers, refineries, power plants and industrial RO plants across Muscat, including Al Rusayl, Sohar, Ghubrah and surrounding areas.
Storage & Safety: Store in the original container in a cool, dry place at your Muscat facility, away from direct sunlight and heat sources. Use appropriate PPE (goggles, gloves, apron) during handling. Avoid contact with eyes and skin. Refer to the Technical Data Sheet (TDS) and MSDS for detailed safety and dosage information.
Related Products: Explore our RO Disinfectant Chemicals for SWRO Desalination, Low pH RO Antiscalant, and RO Membrane Cleaner for a complete RO chemical programme.